Feedthru EMI-RFI Filters DC T CIRCUIT
Technical Characteristics
Current
- Up to: 15 A
Voltage
- Minimum : 50 V
- Maximum : 300 V
Insertion Loss
- Minimum : 5 dB
- Maximum : 80 dB
Capacitance
- From: 0,5 µF
Temperature
- Minimum : -55 °C
- Maximum : 125 °C
Dimensions (OD)
Mounting
- Not available
Sealing
- Not available
Notes
- No special note
Related Standards
MIL
-PRF-15733 compliantRelated Documents
Technical Papers
3D Models
- No Model
Frequently Asked Questions
Related to this product
Q: How is a T Filter Built?
A three-section filter consisting of two series-connected inductors between the input and output terminals, with a feedthrough capacitor between them from line to ground. The T filter is usually symmetrical (identical inductive elements), but circumstances sometimes warrant use of asymmetrical circuits. A T filter has attenuation characteristics that increase at 60 dB from its cutoff frequency to at least that frequency where it exhibits a minimum attenuation of 60 dB.
T-only filters are the choice when both the input and output impedances are low.